Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector

Product Details
Customization: Available
After-sales Service: Warrranty
Warranty: 1 Year
Still deciding? Get samples of US$ 30/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
4100 square meters
  • Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector
  • Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector
  • Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector
  • Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector
  • Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector
  • Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
DM502A
Brand
Dienmern
Customized
Customized
Portable
Portable
Certification
CE, RoHS
Gas
Pm2.5 Tvoc Hcho Pm1 Pm10
Type
Multi-Function Air Quality Detector
Product Name
Multi-Function Air Quality Detector
Material
ABS
Color
White
Screen
LCD Screen
Pm2.5 Sensor Technolology
Laser Scattering
Hcho/Tvoc Technolology
Semiconductor Sensor
Power Supply
Rechargeable Li-Battery 1500mAh
Certificate
CE RoHS
Weight
350g
Product Size
155*87*35mm
Transport Package
Netural Gift Box
Specification
20cm*13cm*5cm
Origin
Guangdong, China
HS Code
9027100090

Product Description

Product Description

 

Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho DetectorQuality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho DetectorQuality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho DetectorQuality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho DetectorQuality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho DetectorQuality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho DetectorQuality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector

 
item
 
Air quality monitor
 
Warranty
 
1 year
 
Type
 
portable gas analyzer
 
Customized support
 
OEM, ODM, OBM, Software reengineering
 
Place of Origin
 
China
 
 
 
Guangdong
 
Brand Name
 
Dienmern
 
Model Number
 
DM502
 
Material
 
ABS
 
Color
 
white
 
Display
 
LCD Display
 
Power supply
 
Rechargeable Li-battery 1500mah
 
PM2.5 Sensor
 
Laser Scattering
 
HCHO/TVOC Sensor
 
Semiconductor sensor
 
PM2.5 Measure Range
 
(0-999 ug/M³)
 
HCHO Measure Range
 
( 0.001-1.999 Mg/M³)
 
TVOC Measure Range
 
(0.001-9.999Mg/M³)
 
Weight
 
350g




Company Profile
Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector
Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector
Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector




Langder Technology Co.,Ltd is a modernized comprehensive scientific research enterprise which was established in March 2013, located in Shenzhen City, Guangdong Province China. 
It is mainly in the business of research and development, production, sales of all kinds of Testing instruments and tools , It has established extensive cooperative relations with partners 
in Netherlands,Spain, Germany ,France, Britain, Poland, Switzerland,Italy,Ireland, Romania,Chile, Mexico, the United States,Japan,korea etc. 
At present, the factory is mainly producing and supplying : 

1. All kinds of air quality montior detectors 
including : 
-CO2 Meter with  wirelss TUYA WIFI app 
-WALL mount CO2 Meter
-Mini Smart CO2 Meters
-Mult-function Air quality monitor test CO2  pm2.5,PM1.0,PM10,HCHO,TVOC
2. Decibel Meter
3.Decibel & CO2 Meter
4.Ozone ( O3 ) Meter
5.NH3 Detector Meter
6.Weather station with TUYA WIFI APP
7.Alcohol Tester
8.Radiation detector

our ceritificates : CE, ROHS, PSE Battery MSDS 
Since its establishment , the Company has won the title of China's national high-tech enterprise and is the top quality merchant of Alibaba for years,
Production scale has 3000 square meters, and with 100 employees. 
Langder has a strong independent research and development team, all Products are from its own private designs and have the apperance patents. 
It not only provides system solutions for various industries, but also provide product design and OEM services for customers .


Quality Assurance New Advanced Laser Sensing Technology for Optimal Air Monitoring Highly Sensitive Pm2.5 Tvoc Hcho Detector
 
 
 
FAQ

1 Q: What the test index are include for air quality monitor?
A : PM2.5: is main for smog(PM1.0 and PM10 are the same); HCHO: is for formaldehyde; TVOC: is main for benzene,etc Volatile organic compounds; AQI: is for Integrated air quality index.


2. Q: What is the safe range for formaldehyde (HCHO) and TVOC?
A : HCHO≤ 0.10mg / m3 TVOC≤ 0.60mg / m3 According to ("indoor air quality standards" GB / T 18883-2002 and GB 50325-2001 Class II civil construction).


3 Q: What is the standard range for PM2.5?
A: Good 0~12 Medium 12~35 safe value 35~70 Unhealthy more than 70


4 Q: Why do I need to calibrate(Just HCHO and TVOC need to calibration, PM2.5 and AQI no need)? A :Our products work in the form of outdoor formaldehyde-free air sampling as a benchmark, and then get indoor air formaldehyde content as a comparison, so the new machine products for a long time not used, the detection of environmental temperature changes, need to calibrated first and then tested, the value of this calibration for the subsequent detection of the accuracy of a great relevance.Calibration environment must avoid spices,perfumes, paint, cigarettes, air fresheners,alcohol and other chemical pollutants, so as not to damage the sensor.
 

5.Q: Why PM2.5 readings with the published value on the site is not the same? A : Because the location and conditions of the test is difficult to reconcile with the weather station in the city there are several sampling points, each sampling point measured data are also very different, the sampling point of the location is strictly required; height 3 to 30 meters, air circulation, can not be close to the chimney, furnace and other obvious sources of pollution. And there are no high-rise buildings, trees or other obstructions that can impede the flow of ambient air around the instrument.

6 Q: Why is the PM2.5 test value always changing? A : PM2.5 data are changing all the times, with the air, wind, humidity and other environmental factors change, in the room smoking, cooking fumes, car exhaust emissions, coal, chimney,furnace Such as pollution sources will change the PM2.5 value of this area, resulting in differences in the detection data.

7 Q: Why does the products make a sound when working? A : As PM2.5 detection need to collect a lot of mobile air, the inner fan needs strong operation to ensure accurate detection.

8 Q: How much range of detection of formaldehyde concentration detector,how many square meters? A : Test area≤ 50m3, room should be set 1~3 testing points; 50m3 ≤ Test area≤ 100m3, room should be set 3~5 testing points; ≥100m3, the points should more than 5 ponits. Testing points is on a diagonal or plum blossom evenly distributed, would more better. The height of the sampling point: in principle,consistent with the human breathing. Relative height of 0.5m ~ 1.5m between.

9 Q: which kinds of air index exceeded, would lead to Alarm sound? A: Just HCHO data more than 0.10mg / m3, would lead to Beep sound.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier